Compact thermal core
Corrugated welded plates create high turbulence and strong heat-transfer coefficients, helping reduce footprint compared with many traditional shell-and-tube arrangements.
Power in every flow
Discuss your heating, cooling or phase-change duty with SHINEHEAT.
SHINEHEAT TECH TRADE MARK
Plate shell heat exchanger technology
CoinWave uses a fully welded circular plate pack as the heat-transfer core and places it inside a cylindrical pressure shell. This plate and shell heat exchanger layout gives the unit the high turbulence and close temperature approach of plate technology, while the shell structure supports demanding pressure, temperature, and process conditions.
The result is a compact PSHE solution for heating, cooling, condensing, evaporating, and process heat recovery. CoinWave is selected when users need the efficiency of a plate heat exchanger, the robustness of a shell-type vessel, and a gasket-free plate pack for safer long-term operation.

Product features
Inspired by proven plate & shell heat exchanger principles, CoinWave focuses on high heat-transfer efficiency, low leakage risk, flexible process integration, and customized mechanical design for each duty.

Corrugated welded plates create high turbulence and strong heat-transfer coefficients, helping reduce footprint compared with many traditional shell-and-tube arrangements.

The heat-transfer plates are welded into a sealed pack, removing plate gaskets from the thermal core and improving suitability for temperature, pressure, and chemical challenges.

Separate plate-side and shell-side paths allow engineered flow direction, nozzle position, and plate-pack orientation to match liquid, gas, condensation, or evaporation service.

The shell protects the plate pack, guides shell-side flow, and provides a strong pressure boundary for services that exceed the comfort zone of gasketed plate heat exchangers.

A short and efficient flow path can be configured for demanding duties, including viscous or high-volume services where pressure drop must be carefully controlled.

Thermal area, plate material, shell material, nozzle size, connection location, supports, and inspection scope are customized around the real process conditions.
PSHE construction
CoinWave is built around a welded circular plate stack installed in a cylindrical case. The labelled structure below shows the plate-side inlet/outlet, shell-side inlet/outlet, baffles, plate stack, case, and tail-board that guide the two fluids through separate heat-transfer paths.

The plate-side inlet directs one process stream into the welded plate channels. It is connected to the plate pack so the medium enters the controlled, high-turbulence heat-transfer path.
The plate-side outlet collects the medium after it has passed through the plate channels and completed heat exchange through the circular plate surfaces.
The upper baffle closes and guides the upper end of the plate-side flow path. It helps separate the two media and supports stable distribution into the plate pack.
The first plate forms the starting heat-transfer surface of the plate stack. Its port opening and pressed geometry help define the plate-side channel path.
The plate stack is the main heat-transfer core. Spoilers disturb the flow, improve turbulence, reduce stagnant zones, and increase heat-transfer efficiency inside the compact PSHE core.
The baffle plate controls internal flow direction around the plate stack. It helps guide the shell-side medium across the heat-transfer surfaces instead of allowing short-circuit flow.
The case is the cylindrical pressure shell around the plate stack. It contains the shell-side medium, protects the welded plate pack, and provides the main pressure boundary.
The shell-side inlet introduces the second process stream into the case. Its position can be engineered for the required shell-side flow direction, pressure drop, and nozzle size.
The shell-side outlet discharges the shell-side medium after it has flowed around the plate stack and exchanged heat through the welded plate surfaces.
The tail-board closes the lower section of the plate assembly and supports correct positioning of the plate stack inside the case during assembly and operation.
The lower baffle completes the lower flow-guiding structure. It supports the assembled core, helps maintain fluid separation, and provides a stable base interface for the unit.
Working principle
In a plate shell heat exchanger, heat moves through the plate wall that separates the two process streams. One fluid passes through the welded plate channels, while the second fluid flows around the plate pack through the shell side.
The corrugated plates create turbulence and help avoid laminar flow, improving heat transfer between the plate surface and the moving media. For gas and condensing duties, shell-side nozzle size and location can be adjusted to handle larger volume flow or condensate removal more effectively.

Industry applications
Following the typical application logic of plate & shell heat exchanger technology, CoinWave can be engineered for single-phase liquid duties, gas heating or cooling, vapor condensation, evaporation, and industrial process heat recovery.
For water heating, oil cooling, product heating, product cooling, interchangers, and subcoolers, CoinWave uses corrugated plates to create turbulent liquid flow and efficient plate-surface heat transfer.
Gas duties often require larger volume flow and flexible nozzle design. CoinWave can place gas on the shell side, using larger shell nozzles and adjusted plate-pack orientation for process gas heating, cooling, and recovery.
For steam, refrigerant, solvent, vent, and vapor-recovery condensation, shell-side layout can support vapor distribution, condensate drainage, inert-gas removal, and integrated condensate handling where required.
Evaporation can be arranged with variable shell-side nozzle sizing and tailored flow distribution for refrigerant flooded evaporators, DX evaporators, combined evaporators, and liquefied gas regasification services.
Manufacturing facility
CoinWave production emphasizes controlled welding, repeatable fabrication, and strict inspection from raw material preparation to final pressure testing.

Controlled plasma welding supports consistent weld beads and stable penetration for the plate pack.

Programmed welding parameters help improve repeatability across plate pairs and production batches.

Polishing and component preparation improve cleanliness, fit-up, and final assembly quality.

Core pressure tests and final inspection verify integrity before shipment and installation.
Engineered-to-order data
CoinWave is sized from real process data. Share the following conditions and SHINEHEAT engineers can recommend the heat-transfer area, plate corrugation concept, shell configuration, material, nozzle arrangement, and pressure-vessel code.
Technology comparison
CoinWave is often considered when a process needs the heat-transfer intensity of plate technology, the pressure boundary of a shell-type vessel, and a more compact arrangement than many shell-and-tube replacements.
| Selection point | CoinWave plate shell heat exchanger | Gasketed plate heat exchanger | Shell and tube heat exchanger |
|---|---|---|---|
| Heat-transfer efficiency | High turbulence from corrugated welded plates | High efficiency but gasket-limited by service | Reliable, usually larger surface area required |
| Leakage control | Fully welded plate pack, no heat-transfer gaskets | Depends on gasket material and compression | Welded tubes and tube sheets, robust construction |
| Footprint | Compact PSHE shell with dense plate surface and short flow path | Compact but limited for severe duties | Often larger and heavier for the same duty |
| Nozzle and layout flexibility | Shell nozzles, plate-side nozzles, supports, and orientation can be duty-specific | Nozzle position is constrained by frame and plate port geometry | Highly customizable but usually with larger size and weight |
| Best fit | Liquid, gas, condenser, evaporator, high-pressure, and compact process duties | Clean, moderate pressure and temperature services | Large flow, heavy-duty, highly standardized plant services |
FAQ
A plate and shell heat exchanger, or PSHE, uses a welded plate pack inside a pressure shell. One fluid flows through the plate-side channels and the other flows through the shell side, combining plate-type heat-transfer efficiency with shell-side mechanical strength.
Yes. CoinWave uses a fully welded plate pack, so the main heat-transfer core does not rely on gaskets between plates. This improves reliability for severe industrial temperature, pressure, and chemical conditions.
Typical applications include chemical processing, petrochemical heat recovery, refrigeration, energy systems, liquid heaters and coolers, gas heaters and coolers, steam and solvent condensers, refrigerant condensers, evaporators, and vapor-recovery services.
Yes. Gas can be placed on the shell side when large volume flow or larger nozzle sizes are required. The shell nozzle position and plate-pack orientation can be engineered to support process gas heaters, gas coolers, compressor aftercoolers, and gas heat-recovery duties.
CoinWave can be evaluated for steam condensers, refrigerant condensers, solvent condensers, vapor-recovery condensers, flooded evaporators, DX evaporators, combined evaporators, and regasification services. Final design depends on phase behavior, nozzle sizing, drainage, pressure drop, and control requirements.
In many compact heat-transfer duties, CoinWave can be evaluated as an alternative to shell and tube equipment. Final suitability depends on fouling, allowable pressure drop, cleaning method, material, design pressure, and process code requirements.
CoinWave can be configured with stainless steel, duplex, 904L, 254 SMO, titanium, nickel alloy, C22/C276, carbon steel shell, or other project-specific materials. Pressure-vessel design can follow ASME VIII Div.1, PED/EN 13445, or other applicable project standards.
Please provide fluid names, phase, properties, flow rates, inlet and outlet temperatures, operating and design pressure, allowable pressure drop, material preference, fouling tendency, nozzle standard, installation orientation, and required certification or pressure-vessel code.
New Selection Knowledge
See how circular plate-pack geometry and movement allowance inform cyclic-duty selection—and which pressure, temperature and start-stop data are still required before fatigue verification.
Cyclic-duty selection path
Use these guides to prepare your enquiry. Final selection depends on your process conditions and project requirements.
Considering COINWave for your process? Share the fluid conditions, heat duty or flow rates, temperatures, operating and design pressures, allowable pressure drop and installation constraints. For cyclic duty, also provide start-up, shutdown and pressure/temperature cycling details.
Send an Enquiry Prepare Process Data
Preparing process data does not submit an enquiry. Use the contact form to send your question or requirements.
Compare SHINEHEAT solutions for fouling fluids, compact high-temperature and high-pressure duties, large-flow welded plate services, and gas-to-gas or gas-to-water heat transfer applications.
Spiral plate heat exchanger for fouling, viscous, slurry, and solids-containing fluids.
Compact bloc-type welded plate heat exchanger for high-temperature and high-pressure duties.
Welded plate heat exchanger with efficient counter-current flow and multiple plate patterns.
Welded plate heat exchanger for gas-to-gas and gas-to-water heat transfer duties.
Not sure which product fits your process? Send operating conditions and SHINEHEAT engineers can recommend the suitable heat exchanger type.
Request Selection SupportNeed help? Our team is just a message away